SPA START-UP cont...
FILLING THE SPA WITH WATER cont...
4) Fill the tub from the circulation pump line until water level is above
the foot-well.
Note: This will purge all the air out of your circulation pump.
An air lock can cause damage to your circulation pump
and is not covered under warranty.
5) Once the water level is filled over the foot-well, you can pull the
hose out of the circulation line and continue filling the spa from the
filter well.
6) Fill the spa to the bottom of the pillows. Note: DO NOT OVER-FILL
YOUR TUB!
7) With the front panel off, verify there are no leaks at the pump
unions. Note: Pump unions can become loose during shipping.
Verify that there are no leaks during filling of the spa.
8) Reinstall the circulation pump and all filters.
TURNING THE POWER ON
Turn the power to the spa on at the main circuit breaker. Verify that
your spa has no error codes. (See page 47) Verify you have good
circulation in your spa. Your pumps will come on in cycles, for 1
minute each cycle.
VERIFYING WATER CIRCULATION
1) Open all the jets.
2) Press and hold the Pump 2 key for 5 seconds.
3) Make sure each seat has water flow. Note: On certain spas there is
a diverter valve. Verify where the diverter valve is located.
4) Press and hold pump 2 key again to shut off all jets.
TESTING THE GFCI BREAKER
NOTE: The electrical service panel for your spa should be
equipped with a GFCI breaker. To avoid the risk of electrical
shock, perform the following safety test before each use of
your spa.
1) Make sure the power is turned on at the electrical service panel.
2) Turn on the GFCI breaker. If the breaker stays on, it is functioning
properly.
DANGER: RISK OF ELECTRICAL SHOCK
If the GFCI breaker fails to operate as described, there is a possibility
of an electric shock if the spa is used. Shut off the power at the main
electrical service panel until the source of the problem has been
identified and corrected by a licensed electrician or qualified spa
technician.